All insights

How preserved tendons resist dislocation after SPAIRE

Clinically reviewed by Professor Paul Lee
How preserved tendons resist dislocation after SPAIRE

What the strap effect actually means

When surgeons talk about the 'strap effect', they are describing something precise: the way the obturator internus tendon, left intact during a SPAIRE hip replacement, sits across the back of the joint and acts as a biological tether. Think of it less like a seatbelt that clicks into place only when needed, and more like a strap that is always there — holding the femoral head in position whether the surrounding muscles are actively working or simply at rest.

That distinction matters. The tether works through two separate mechanisms: the pull of active muscle contraction and the quieter, continuous resistance of passive tissue tension. A patient does not need to consciously squeeze a muscle to benefit — the resting tone of the intact tendon is doing part of the job around the clock.

In a traditional posterior hip replacement, this tendon is divided to gain surgical access, removing the tether from day one of recovery. SPAIRE is designed to leave it undisturbed, so the stabilising effect is present from the moment the patient wakes up.

The strap effect is a clinical concept, not a guarantee. It explains the biomechanical rationale for soft-tissue preservation — and as the evidence continues to develop, it remains one important factor among several that shape stability after surgery.

The obturator internus tendon's unusual route

Anatomy rarely arranges itself conveniently — but the obturator internus tendon is something of an exception. Its route through the pelvis follows a path that, by chance of geometry, places it in almost exactly the right position to hold the hip joint together from behind.

The tendon begins inside the pelvis, where the obturator internus muscle lines much of the inner pelvic wall. To reach the femur, the tendon must exit the pelvis — and it does so through the lesser sciatic foramen, a notch low on the back of the hip bone. At this point it bends sharply around the smooth cartilage of the lesser sciatic notch, much like a rope looping over a pulley. That bend redirects the tendon outward and upward, whereupon it crosses the posterior surface of the femoral head — directly behind the ball of the hip joint — before inserting on the medial surface of the greater trochanter.

The pulley arrangement is what makes this clinically significant. Because the tendon wraps around the notch and then runs across the back of the femoral head at or just below the joint's true centre of rotation, it is geometrically positioned to resist the direction of force most associated with dislocation after a posterior hip replacement: the backward and downward translation of the femoral head.

Preserving this anatomical route intact is the prerequisite for the strap effect to function. Divide the tendon — as traditional posterior approaches do — and the pulley geometry is gone.

Active contraction and resting tension — two ways the strap works

Two separate physical mechanisms explain how the preserved tendon supports the joint — and they operate at different times.

During active movement — standing, walking, or repositioning — the obturator internus muscle contracts and pulls through the tendon. Because the tendon runs directly across the posterior femoral head, that contractile force draws the ball of the joint backwards into the socket, resisting the tendency to translate posteriorly at the moments when the hip is most loaded.

The second mechanism is quieter. Tendon and connective tissue are viscoelastic: they maintain a continuous resting tension even when the surrounding muscle is completely relaxed. This passive component means the tether is never fully 'off' — not during sleep, early physiotherapy, or the unguarded moments that account for a significant proportion of post-operative dislocations. Sitting forward to put on shoes, reaching towards the floor: these are passive, inattentive movements, yet some degree of mechanical resistance remains present without any deliberate muscle activation.

Component position, implant design, and individual anatomy all contribute to overall hip stability alongside this soft-tissue layer. But the dual nature of the strap effect — active during movement, passive at rest — helps explain why preserving the tendon intact matters across the full spectrum of early recovery, not only during deliberate exercise.

Next steps

Where to go from here

These routes are selected from the topic and purpose of this article. They are guidance, not a diagnosis or treatment recommendation.

Learn more

Explore SPAIRE hip replacement

Talk to the team

Book a free discovery call

Proprioception — the neurological layer of protection

The mechanical strap effect has a neurological counterpart. Within the tendons and muscle bellies of the short external rotators — the group preserved intact during SPAIRE — lie mechanoreceptors: Golgi tendon organs and muscle spindles that continuously report joint position and loading to the nervous system. This is the hip's own position-sensing system, operating below conscious awareness.

When these structures remain undivided, that signalling continues uninterrupted after surgery. The nervous system can detect when the joint approaches an extreme or subluxating position and trigger a reflexive protective response — a guarding mechanism that does not depend on the patient consciously remembering to move carefully.

Dividing the short external rotators, as traditional posterior approaches do, severs these mechanoreceptors along with the tendons. The joint becomes neurologically unresponsive to positional threat until the tissues biologically heal and neural pathways regenerate — adding a sensory deficit to the mechanical one during the same 90-day window of heightened vulnerability.

In clinical thinking, this proprioceptive layer is regarded as a likely complement to the mechanical strap. Researchers have not yet run controlled trials to measure it directly, so it remains a reasoned anatomical and neurophysiological hypothesis rather than a quantified outcome — something to hold alongside the evidence, not instead of it.

What traditional posterior surgery removes — and why precautions exist

In a traditional posterior total hip replacement, the piriformis and obturator internus must be divided to gain adequate access to the joint — a deliberate surgical trade-off that has supported an established record over decades. The consequence is straightforward: the anatomical structures on which the strap effect depends are no longer present. Without them, neither the passive tether nor the intact mechanoreceptor network can function until the divided tissues have had time to heal.

Hip precautions — avoiding hip flexion beyond 90 degrees, crossing the legs, or turning the foot inward — exist as a direct compensatory response to this deficit. They are designed to keep the unreinforced joint away from positions most likely to cause posterior dislocation during the healing window. Behavioural rules, in effect, substitute for the anatomy that was set aside to allow surgical access.

The clinical consequences of dislocation during this period help explain why the design matters. In traditional posterior approach outcomes, 57% of patients who experience a dislocation go on to have more than one, and 45.6% require revision surgery within two years. These figures do not come from SPAIRE comparisons — they reflect the burden that dislocation carries in conventional posterior practice, establishing the context rather than a head-to-head result.

SPAIRE's underlying logic follows directly from this: if precautions exist to compensate for an absent soft-tissue layer, preserving that layer intact is an attempt to make the compensation unnecessary.

Clinical perspective and realistic expectations

Professor Paul Lee, who refined SPAIRE during fellowship training at the Exeter Hip Unit under Professor Timperley, positions the strap effect as central to how soft-tissue preservation changes the stability equation for selected patients — not as a guarantee, but as an anatomical rationale for approaching the posterior joint differently from the outset. In his practice, the concept explains why keeping the obturator internus and piriformis intact is a deliberate design choice rather than a secondary consideration.

In clinical terms, the strap effect is one factor within a larger picture. Careful component positioning, appropriate implant selection, and individual recovery planning remain essential regardless of which surgical approach is used. Whether SPAIRE is appropriate depends on a patient's anatomy, surgical history, body habitus, and other individual circumstances — it suits selected patients, not every patient. Peer-reviewed evidence specific to the strap effect as an isolated variable remains limited; the concept is applied in clinical practice to explain the reasoning behind preservation, not to cite a controlled trial result.

Patients who have followed the argument across these sections — the obturator internus's unusual pulley route around the lesser sciatic notch, the way passive viscoelastic tension holds even at rest, the mechanoreceptors that continue signalling through the immediate recovery period — are better placed to have a genuinely specific conversation with a specialist. Not simply 'is this technique available?' but: 'given my anatomy and risk profile, does the case for preserving this tissue apply to me?' That is the question the strap effect, properly understood, makes it possible to ask.

Frequently Asked Questions

  • The strap effect describes how the obturator internus tendon, left intact during SPAIRE, sits across the back of the hip joint and acts as a biological tether. It works through both active muscle contraction and passive tissue tension to resist the femoral head translating backwards.
  • The tendon exits the pelvis through the lesser sciatic foramen and wraps around the lesser sciatic notch like a rope over a pulley. This routing positions it directly behind the femoral head where it resists the backward and downward forces most associated with posterior dislocation.
  • No. The intact tendon maintains passive viscoelastic tension even at rest. This means the tether provides mechanical resistance during both active movement and quiet moments—including sleep or early physiotherapy—without requiring conscious muscle activation.
  • Mechanoreceptors—Golgi tendon organs and muscle spindles—within the preserved short external rotators continuously signal joint position to the nervous system. This proprioceptive feedback allows reflexive protective responses to extreme positions, a safeguard absent in traditional approaches until tissues regenerate.
  • Traditional posterior surgery divides the obturator internus and piriformis to access the joint, removing the biological tether and mechanoreceptors. Hip precautions compensate for this loss during the 90-day healing window until the divided tissues regenerate and regain function.

Next steps

Where to go from here

These routes are selected from the topic and purpose of this article. They are guidance, not a diagnosis or treatment recommendation.

Learn more

Explore SPAIRE hip replacement

Read the reviewed SPAIRE hip replacement pathway, including who it may help and what happens next.

Talk to the team

Book a free discovery call

A non-medical call with the team to understand services and choose the right booking route.

Legal & Medical Disclaimer

This article is published by SPAIRE Hips for general information and education only. It does not constitute medical advice, diagnosis, or treatment.

Always seek personalised advice from a qualified healthcare professional before making decisions about your health. SPAIRE Hips accepts no responsibility for errors, omissions, third-party content, or any loss, damage, or injury arising from reliance on this material.

If you believe this article contains inaccurate or infringing content, please contact us at [email protected].

For urgent medical concerns, contact your local emergency services.
Clinically led by Professor Paul LeeHip preservation and SPAIRE expertise
Last reviewed:
  • Honorary Professor, University of Lincoln
  • Ambassador, Royal College of Surgeons Edinburgh
Privacy & Cookies Policy