All insights

How SPAIRE differs from traditional posterior hip replacement

Clinically reviewed by Professor Paul Lee
How SPAIRE differs from traditional posterior hip replacement

What the traditional posterior approach involves

The posterior approach is the most widely performed route to total hip replacement in the UK. Its popularity rests on practical foundations: it gives surgeons a generous view of the joint, works across a broad range of body types and hip conditions, and is familiar to the large majority of orthopaedic teams. For most patients, it remains a reliable and well-established operation.

Reaching the hip from behind, however, means working through a group of small but important muscles and tendons at the back of the joint — collectively known as the short external rotators. In a standard posterior approach, several of these structures are detached to allow the joint to be opened safely. The tendons divided include the piriformis, the gemelli, and both the obturator internus and obturator externus. Once the new hip has been implanted, these tendons are carefully repaired back to the bone before the wound is closed.

That repair is necessary, but it introduces a recovery constraint. Reattached tendons need time to heal back to the bone before they can reliably support and protect the joint — a process that typically takes several weeks. To reduce the risk of dislocation during this window, patients have historically been advised to follow strict movement restrictions: avoiding bending the hip past 90°, crossing the legs, or rotating the foot inward. These hip precautions have traditionally been maintained for up to 90 days. Approximately 57% of patients who do dislocate following a posterior hip replacement go on to dislocate more than once, underscoring why protecting the healing repair during this early period matters.

The one structural change that defines SPAIRE

The acronym captures the precise change: SPAIRE stands for Saves Piriformis And Obturator Internus, Repairs Obturator Externus. First formally described in 2016 by Professor A. J. (John) Timperley and his team at the Exeter Hip Unit, it takes the familiar posterior route — same skin incision, same patient positioning, same general anatomical corridor — and makes one deliberate alteration to what happens once the hip is exposed.

In a standard posterior approach, all four short external rotator tendons are divided to open the joint. SPAIRE changes this at a single point: rather than detaching the piriformis and obturator internus, the surgeon works carefully around them, leaving both tendons continuous and attached to bone throughout the operation. Only the obturator externus — the most inferior of the group, lying just below the joint line — is detached and then repaired at closure.

The piriformis and obturator internus run across the back of the hip, draping over the posterior aspect of the femoral head as they travel from the pelvis to the upper femur. In a SPAIRE procedure, both remain undisturbed in that position for the entirety of the operation. Because they are never cut, they require no healing period — they are structurally intact the moment the patient wakes from the anaesthetic.

That single difference in tendon handling is the foundation of everything SPAIRE is designed to achieve. The posterior approach retains its well-understood exposure advantages; the modification lies entirely in the surgeon's relationship with those two posterior stabilisers.

Why preserved tendons may support stability

Two mechanisms are proposed to explain why preserving these tendons may support joint stability from the moment the operation ends.

The first is mechanical. The obturator internus tendon runs across the back of the joint, draping over the posterior surface of the femoral head close to the centre of rotation. Because it is never divided in SPAIRE, it remains in that position throughout the procedure — intact before the patient leaves the operating theatre. The literature describes this as a 'strap effect': the tendon may act as a passive biological tether that resists the new femoral head from sliding backwards. The analogy is less like a muscle actively working against gravity, and more like a seatbelt that is already buckled — a restraint that is simply present, rather than one that must first be re-attached and then healed before it can function.

The second mechanism is neurological. The short external rotators contain mechanoreceptors — specialised nerve endings, including Golgi tendon organs and muscle spindles, that continuously monitor joint position and movement. In an intact tendon, these sensors may help the brain regulate the hip's position instinctively, providing a degree of self-protection against extreme ranges of motion. When those tendons are divided in a traditional posterior approach, this proprioceptive signalling is interrupted until neural regeneration occurs.

The strap effect is anatomically well-grounded and forms a coherent part of the SPAIRE rationale. The proprioceptive mechanism is supported by basic science and the theory is plausible, but clinical measurement of its contribution to patient outcomes remains an active area of research. Neither mechanism should be read as a guarantee against dislocation — both describe what the design is intended to support, not what it universally delivers.

What the difference means for early recovery

Movement restrictions after hip replacement are shaped directly by what happened in theatre. After a traditional posterior approach, patients typically receive formal hip precautions — no bending past 90°, no crossing the legs, no twisting inwards — while the repaired tendons heal, a process that can take several weeks. SPAIRE changes this position from the first moment of recovery.

Because the piriformis and obturator internus were never divided, there is nothing in those tendons that requires a healing period before they can function. For selected patients, that intact state may translate into an earlier return to fuller movement: getting up from a chair with less restriction, managing stairs sooner, and feeling more confident in the everyday movements that the first weeks at home demand. How much freedom is appropriate in a given case still depends on individual anatomy, implant choice, and the operating surgeon's clinical assessment — the absence of divided tendons does not replace a careful, individually paced recovery plan.

The clinical picture, while still maturing, points in a positive direction. Charity et al. (2023) found that use of the SPAIRE approach may be associated with improved return to pre-injury level of mobility compared with the lateral technique — a finding cited 24 times in the literature. A 2025 scoping review by Kenanidis et al. of 57 studies covering piriformis-preserving total hip arthroplasty noted potential benefits for stability and functional outcomes in short-term follow-up, while explicitly calling for higher-quality prospective evidence. The NIHR HIPSTER trial is designed to provide exactly that. Taken together, the early data support what the design is intended to achieve; larger trial results will determine how widely and confidently that applies.

Suitability, limitations, and when SPAIRE can be extended

Not every patient is an ideal candidate, and being clear about that is part of responsible surgical decision-making.

SPAIRE can be technically more demanding in patients with small anatomy, reduced femoral offset, or a significant external rotation deformity. In these cases, the more limited soft-tissue exposure means that positioning implants with precision requires additional care. Where this applies, robotic-arm assistance — such as the Mako system — is used in some surgical pathways to support sub-millimetre accuracy, compensating for what the restricted access makes harder to judge by feel alone. Robotic assistance is one tool in managing that challenge, not a routine requirement for every SPAIRE procedure.

One practical advantage over the direct anterior approach is worth noting. If, during the operation, exposure proves insufficient for safe progression, SPAIRE can be converted intraoperatively to a full standard posterior approach through the same incision — without repositioning the patient. That option does not exist with the direct anterior route, where a change in approach would require a fundamentally different setup. It functions as a genuine clinical safety net rather than a theoretical one.

The direct anterior approach carries its own set of trade-offs: different early-recovery characteristics, but also a risk of lateral femoral cutaneous nerve neurapraxia and a steeper surgical learning curve. Neither approach is categorically superior; they offer different profiles of advantage and risk.

Which approach is appropriate depends on an individual's anatomy, pre-operative imaging, and clinical circumstances — a decision made through surgical assessment, not a single rule that applies to everyone.

Where the evidence stands and what trials are measuring

Two NIHR-funded trials sit at the centre of the current evidence picture. The HemiSPAIRE RCT — recruiting between November 2019 and April 2022 — compared SPAIRE directly with the standard lateral approach for hip hemiarthroplasty, using the De Morton Mobility Index as its primary measure alongside dislocation rates and Oxford Hip Score. Preliminary data from more than 1,000 primary total hip replacements were presented in 2024. The HIPSTER trial, still recruiting, extends that work into a three-arm comparison against a robotic-assisted standard posterior approach — the most methodologically rigorous test yet run on the technique.

The available evidence base spans expert narrative, cohort data, and early-phase trial results. Together with the Charity and Kenanidis findings discussed above, this points in a consistent direction — but is not yet definitive at the level of long-term implant survivorship. That is a normal position for a technique first formally described in 2016, not a reason for concern. The proprioceptive dimension — whether intact mechanoreceptors actively protect the hip in the months following surgery — remains theoretically well-grounded but has not yet been robustly measured in prospective clinical studies; it is one of the questions the ongoing trials may begin to address.

For someone weighing approach options, a concrete question to raise with a surgeon is whether their particular anatomy — femoral offset, rotation profile, and bone geometry — makes SPAIRE a suitable fit. That is where the current evidence, and the clinical judgement it informs, gets applied.

  1. [1] The SPAIRE Technique Allows Hip Arthroplasty with Division of Only the Obturator Externus Tendon (2018). (2018).
  2. [2] A Standard of Care in Hip Arthroplasty: Routine Use of the Tendon-Sparing SPAIRE Technique with MAKO Robotic Assistance (2024). (2024). https://doi.org/10.1302/1358-992x.2024.16.030 https://doi.org/10.1302/1358-992x.2024.16.030

Frequently Asked Questions

  • SPAIRE stands for Saves Piriformis And Obturator Internus, Repairs Obturator Externus. It describes a modern posterior approach to total hip replacement that preserves two key posterior stabilising tendons instead of dividing them.
  • The standard posterior approach divides all four short external rotator tendons to access the hip joint. SPAIRE preserves the piriformis and obturator internus, leaving only the obturator externus to be detached and repaired, which may reduce healing time.
  • Two mechanisms are proposed. First, a mechanical 'strap effect': the intact obturator internus tendon drapes over the posterior femoral head, acting like a restraint that is present immediately without requiring healing. Second, proprioceptive feedback: intact mechanoreceptors in the tendons may help the brain protect the hip against extreme motion instinctively.
  • Because the piriformis and obturator internus are never divided, they need no healing time. For selected patients, this may allow earlier, fuller movement: rising from chairs with less constraint, managing stairs sooner, and performing everyday movements with greater confidence. However, appropriate progression depends on individual anatomy and surgical assessment.
  • SPAIRE can be technically demanding in patients with small anatomy, reduced femoral offset, or significant external rotation deformity. Robotic-arm assistance may support accuracy in these cases. SPAIRE can be converted intraoperatively to a standard posterior approach if needed, offering a clinical safety net the direct anterior approach cannot provide.

Next steps

Where to go from here

These routes are selected from the topic and purpose of this article. They are guidance, not a diagnosis or treatment recommendation.

Recovery route

Explore recovery guidance

Continue with practical recovery and patient-journey information.

Learn more

Explore private hip replacement

Use a structured overview to narrow down the most useful next step for your situation.

Talk to the team

Book a free discovery call

A non-medical call with the team to understand services and choose the right booking route.

Legal & Medical Disclaimer

This article is published by SPAIRE Hips for general information and education only. It does not constitute medical advice, diagnosis, or treatment.

Always seek personalised advice from a qualified healthcare professional before making decisions about your health. SPAIRE Hips accepts no responsibility for errors, omissions, third-party content, or any loss, damage, or injury arising from reliance on this material.

If you believe this article contains inaccurate or infringing content, please contact us at [email protected].

For urgent medical concerns, contact your local emergency services.
Clinically led by Professor Paul LeeHip preservation and SPAIRE expertise
Last reviewed:
  • Honorary Professor, University of Lincoln
  • Ambassador, Royal College of Surgeons Edinburgh
Privacy & Cookies Policy
Package from£17,800What is in it